Medical Lab 60L 100L 170L 190L Hydrogen Peroxide Plasma Autoclave Low Temperature Cassette H2O2 Plasma Sterilizer
Parameters:
Chamber material: The chamber structure is rectangular, can improve the space utilization; It use aluminum 5052 alloy; thickness ≥ 8 mm, with excellent thermal conductivity, to ensure that hydrogen peroxide to maintain 100% gaseous.
Machine shell material: High Polymer ABS Material
Electrode material: Aluminum alloy material 5052, sheet metal forming, thickness ≥ 3 mm
Sealing door: Use 5052 aluminum alloy material, thickness ≥ 15 mm. With Pneumatic seal system.The door can't open when the machine in processing.
Loading carriage : The removable aluminum alloy punching plates for sterile items, big loading capacity, high space usage.
Door open mode: Automatic.
Hydrogen peroxide filling method: cassette, automatic drive by PLC
Door protection function: With door barrier switch function, when touch the barrier switch, the door automatically stop, to prevent injure to the operator and damage the items.
Chamber temperature heating power: 2.75kw, pre-heating time ≤ 30 min. It can meet the chamber heating power and heating up more faster.
Main body insulation: ≥ 20 mm suction cotton, with a low thermal conductivity, fire performance, anti-aging ability, non-toxic environmental protection and the appearance of high-grade soft texture and so on.
Full automatic control system: LCD touch screen display, PLC intelligent control system. One button to control from start to end and finish automatically with showing temperature, pressure, sterilization time. The system can maintenance and upgrade.
Printer: Adapting to micro printer to printing each data of every minute during the sterilization process, also can storage permanently. It can print the following data: process name, sterilize date, sterilize time, sterilization start&end time, the variation data of pressure and temperature during the sterilization process, stage time and end status and other information, also provide print samples.
PLC: Use imported Siemens smart series PLC control system.
Display: 7-inch color touch screen, communication rate ≥ 19.2 Kbps.
Display status: Temperature, pressure, time, cycle mode, process stage and alarm information, and provide the actual interface photo.
USB-port :last 60-times past sterilization cycle records.
Biological Indicator incubator: Microcomputer-controlled biological indicator.range of ≤± 3ºC temperature control accuracy; temperature can be set
Pressure sensor: imported from Japan, to ensure that the chamber pressure is accurate and effective.
Temperature sensor: within precise range of 50ºC±3ºC.
Program System: There are two procedures: Long cycle and short cycle. enhanced cycle ≤ 50 minutes, fast cycle ≤ 30 minutes.
Vacuum system: Brand vacuum pump, the vacuum speed is fast and the service life is long.
Vacuum pump phase sequence protection: With a vacuum pump phase sequence protection device to prevent the power supply phase sequence changes, to protect the vacuum pump.
Oil mist filter: The product has an exhaust oil mist filtration system, which can recover oil mist, avoid oil mist into the air, and pump the pump oil back to the pump to reduce fuel consumption.
Air filter: The filter accuracy is less than or equal to 0.2μm.
Plasma power: using transistor control power, power ≤ 500W, strong analytical ability.
Sterilization effect: Domestic first invent that can make cavity instrument disinfect thoroughly from 2 meters to 4 meters. Offer provincial sterilization effect certificate report.
Heating system: Adapting to anti-explosion and fire resistance heating system, temperature is more precise, more convenient and fast.
Electromagnetic compatibility testing: Provide the provincial testing agencies electromagnetic compatibility test report.
Various protective function: It has set up over temperature protection function and show on LCD screen if fault, to make the after sales-service dealing with fault more efficiently.
Caster: Yes.
Alarming system: cycle completion and errors audio warning .
Details:
Feedback:
About us:

Chamber material: The chamber structure is rectangular, can improve the space utilization; It use aluminum 5052 alloy; thickness ≥ 8 mm, with excellent thermal conductivity, to ensure that hydrogen peroxide to maintain 100% gaseous.
Machine shell material: High Polymer ABS Material
Electrode material: Aluminum alloy material 5052, sheet metal forming, thickness ≥ 3 mm
Sealing door: Use 5052 aluminum alloy material, thickness ≥ 15 mm. With Pneumatic seal system.The door can't open when the machine in processing.
Loading carriage : The removable aluminum alloy punching plates for sterile items, big loading capacity, high space usage.
Door open mode: Automatic.
Hydrogen peroxide filling method: cassette, automatic drive by PLC
Door protection function: With door barrier switch function, when touch the barrier switch, the door automatically stop, to prevent injure to the operator and damage the items.
Chamber temperature heating power: 2.75kw, pre-heating time ≤ 30 min. It can meet the chamber heating power and heating up more faster.
Main body insulation: ≥ 20 mm suction cotton, with a low thermal conductivity, fire performance, anti-aging ability, non-toxic environmental protection and the appearance of high-grade soft texture and so on.
Full automatic control system: LCD touch screen display, PLC intelligent control system. One button to control from start to end and finish automatically with showing temperature, pressure, sterilization time. The system can maintenance and upgrade.
Printer: Adapting to micro printer to printing each data of every minute during the sterilization process, also can storage permanently. It can print the following data: process name, sterilize date, sterilize time, sterilization start&end time, the variation data of pressure and temperature during the sterilization process, stage time and end status and other information, also provide print samples.
PLC: Use imported Siemens smart series PLC control system.
Display: 7-inch color touch screen, communication rate ≥ 19.2 Kbps.
Display status: Temperature, pressure, time, cycle mode, process stage and alarm information, and provide the actual interface photo.
USB-port :last 60-times past sterilization cycle records.
Biological Indicator incubator: Microcomputer-controlled biological indicator.range of ≤± 3ºC temperature control accuracy; temperature can be set
Pressure sensor: imported from Japan, to ensure that the chamber pressure is accurate and effective.
Temperature sensor: within precise range of 50ºC±3ºC.
Program System: There are two procedures: Long cycle and short cycle. enhanced cycle ≤ 50 minutes, fast cycle ≤ 30 minutes.
Vacuum system: Brand vacuum pump, the vacuum speed is fast and the service life is long.
Vacuum pump phase sequence protection: With a vacuum pump phase sequence protection device to prevent the power supply phase sequence changes, to protect the vacuum pump.
Oil mist filter: The product has an exhaust oil mist filtration system, which can recover oil mist, avoid oil mist into the air, and pump the pump oil back to the pump to reduce fuel consumption.
Air filter: The filter accuracy is less than or equal to 0.2μm.
Plasma power: using transistor control power, power ≤ 500W, strong analytical ability.
Sterilization effect: Domestic first invent that can make cavity instrument disinfect thoroughly from 2 meters to 4 meters. Offer provincial sterilization effect certificate report.
Heating system: Adapting to anti-explosion and fire resistance heating system, temperature is more precise, more convenient and fast.
Electromagnetic compatibility testing: Provide the provincial testing agencies electromagnetic compatibility test report.
Various protective function: It has set up over temperature protection function and show on LCD screen if fault, to make the after sales-service dealing with fault more efficiently.
Caster: Yes.
Alarming system: cycle completion and errors audio warning .
Details:
Model | HSQ-D100 |
Type | Cassette H2O2 plasma sterilizer |
Heating method | Electric |
Install environment | 5-45ºC |
Sterilizing temperature | 50ºC |
Working pressure | 50pa |
Sterilize agent | Hydrogen peroxide solution(60%H202) |
Sterilizing time | 45-50min |
Parameter display | LCD touch screen |
Door opening method | Automatic |
Cassette | 12pcs/set support 6 sterilization cycles |
![]() |
No. | Model | Volume | Chamber size(L*W*H) | Dimension | P | G.W(kg) | Power supply | Price |
1 | HSQ-D100 | 100L | 700 x 430 x 360mm | 1105×790×1765mm | 3.95 | 340 | AC220V/50HZ | |
2 | HSQ-D130 | 130L | 750 x 450 x 400mm | 1105×790×1765mm | 4.35 | 360 | AC220V/50HZ | |
3 | HSQ-D220 | 190L | 820 x 510 x 460mm | 1105×790×1765mm | 5.15 | 450 | AC220V/50HZ | |
Hydrogen peroxide cassette | ![]() |